DIXI Polytool Application of the Month
Application field: Medical instrument

Step drill
DIXI 1502
Ø6 x 12 x Ø7.50 x 21.50 x Ø8 x 79, Z=2
Automatic lathe with sliding headstock
Stepped drills with internal coolant
| Cutting conditions | |
| Material | Titan Ti6AL4V |
| Cutting data | Vc = 40 m/min |
| n = 1,800 min-1 | |
| Vf = 108 mm/min | |
| Lubricant | Cutting oil |
| Pre-drilling with DIXI 1106 Ø6. | |
| Drilling in one single penetration (pass) | |
| Comments | Tool life is about 1,500 holes per drill. |